[J-GATE3.0] What will be the behavior if the value is not set in [ext_t_state_c] (Closing Conditi...
If the value is not set in [ext_t_state_c] (Closing Condition Session Specified), it will be treated as “0” since the datatype of [ext_t_state_c] (Closing Co... Show Details
[J-GATE3.0] How can we make sure that we don't miss any multicasts during Weekend Testing?
Just same as the normal Production Environment; all the multicasts are available as long as subscribing to multicast from 1 hour prior to online until on... Show Details
[J-GATE3.0]In which case is Login ID locked, and how to unlock the locked Login ID?
In case of wrong password entry, the relevant login ID is to be locked after five attempts. In order to unlock the ID, please download "J-GATE3.0_Password... Show Details
[J-GATE3.0]Please inform us of the trading hour of J-GATE.
Trading hour varies in each products. Please refer to these two parts of [J-GATE3.0 Connectivity Manual Commonalities Appendix]. -5.1 (1)_Time Table Involv... Show Details
[J-GATE3.0]Will the fields with empty remark column on each message in the connectivity guide be ...
As described in “2.1.2 About Structure” on [J-GATE3.0_Connectivity_Manual_Business_Message_part], if there is no description of field for each message, it is... Show Details
[J-GATE3.0] If the expiration date is changed with the delisting of the underlying series of a se...
The dissemination timing of a series information which the expiration date is changed is not decided as “# business days before delisting” but depends on the... Show Details
[J-GATE3.0] What is the configuration unit for MMP (Market Maker Protection)?
MMP configuration is made on each underlying. Since MMP triggering products within an underlying and minimum volume of quantity_protection_q and delta_prote... Show Details
[J-GATE3.0] What is IP address and Port number for J-GATE Login IDs?
Please confirm the User ID Application (setting information) on arrowface. Show Details
[J-GATE3.0] Can the same [execution_event_nbr_u] (execution event number) be set for multiple exe...
Since [execution_event_nbr_u] (execution event number) is set per partition, same value for [execution_event_nbr_u] (execution event number) can be set for e... Show Details
[J-GATE3.0]What is the start time of order receipt on day session in J-GATE?
The start time of order acceptance on day session is 8:00 JST, and the start time of order acceptance and beginning of session in J-NET is 8:20 JST. For d... Show Details