[J-GATE3.0]How to acquire delta queries of DQ124 (Request for acquiring instrument series).
The instruction is as below: (Please also refer to “Example of DRN and timestamp in DQ124 delta queries” in “1.1.2.3 Delta Query” of “J-GATE3.0_Connectivi... Show Details
[J-GATE3.0] In [Table_4.4.5-2 Login acceptance packet] on J-GATE3.0 ITCH Connectivity Manual, it ...
The details of this field is not disclosed on the specification manual provided from the package vendor. In addition, the information in this field is not n... Show Details
[J-GATE3.0] What is the connective destination of TradeGuard?
The address of TradeGuard launch page is provided by Exchange when a Login ID is issued. The address can be found in a CSV file in arrowface. The ad... Show Details
[J-GATE3.0] What is the Non-Cancel Period (NCP)? What is the applicable order, session, and product.
[Non-Cancel Period (NCP)] - Outline To prevent excessive price fluctuation due to order modifications/cancellations just before Itayose, OSE introd... Show Details
[J-GATE3.0]Are there hardware requirements?
There are no specific requirements. Please arrange hardware which meets your company's functionality, performance, and operational requirements. Show Details
[J-GATE3.0] Is there a case that structure 37805 is not set for the answer (DA90) of DQ90(request...
Structure 37805 is always set even when DA90 is divided into segments. There are no case that structure 37805 is not to be set. Show Details
[J-GATE3.0]Is there a standby server for TradeGuard? What will the behavior be in case of a failure?
TradeGuard operates on 2 servers which is synchronized at all times. We will notify the TradeGuard login ID along with IP address for both servers, please c... Show Details
[J-GATE3.0] What is the notation for combination series in TradeGuard (GUI)? (e.g. "<CmbCls SPR>J...
1) Inside parenthesis: Represents types of combination series (SCO series) provided by OSE. <CmbCls SPR> : SCO(Standard Combination) series ... Show Details
[J-GATE3.0] When does the day trading session begin?
The start of day session depends on the product (either 8:45 or 9:00). For more details, please refer to the following sheets on [J-GATE3.0 Connectivity M... Show Details
[J-GATE3.0] Is there a case that orders can be sent although Order rate limit (Limit for number o...
Order Rate Limit is Breached when a tenth of the set Limit is exceeded within a tenth of a second. However, it is not always calculated precisely every te... Show Details
191-200 of Total 300