[J-GATE3.0] Is it possible to continue sending orders from a separate circuit during Storm Control?
As your understanding, it is possible to continue ordering. Since Storm Control is regulated in circuit basis, orders can be placed by using circuits other ... Show Details
[J-GATE3.0] Regarding “Importing limits” on TradeGuard, please explain how to set upper limit val...
Setting new trading risk upper limit value for MAX Size and current upper limit value for others to the CSV file, then importing the CSV file to TradeGuard a... Show Details
[J-GATE3.0] Is there a case that orders can be sent although Order rate limit (Limit for number o...
Order Rate Limit is Breached when a tenth of the set Limit is exceeded within a tenth of a second. However, it is not always calculated precisely every te... Show Details
[J-GATE3.0] Can the trade multiplier in DQ122 (Instrument Class Acquisition Request) be used?
As stated in “3.12.6_Trading Units and Trading Multiplier By Product” of “J-GATE3.0_Connectivity_Manual_Business_Message_part_Appendix”, “There is a Trad... Show Details
[J-GATE3.0] When does the day trading session begin?
The start of day session depends on the product (either 8:45 or 9:00). For more details, please refer to the following sheets on [J-GATE3.0 Connectivity M... Show Details
[J-GATE3.0] Are the dissemination timings for series information different between a newly added ...
The information for a newly added regular series is disseminated between DAY_END and 18:30. The information for a newly added combination series is diss... Show Details
[J-GATE3.0]What is the rule of Price Limit of spread for TSE Mothers Index Futures?
Price Limit for TSE Mothers Index Futures is set as follows and updated on every trade date. Upper Limit : (Upper Limit of Price Limit of Far Contract Mon... Show Details
[J-GATE3.0] Is it mandatory to register MMP user to PTLG?
Same as the Market Information user, since MMP user are not able to place orders, it is not mandatory to register to PTLG. Show Details
[J-GATE3.0] How to change the name of PTLG.
The procedure is as follows: 1. Delete the existing PTLG (Pre-Trade Limit Group). (Since the effective date of deletion is the following business day, the ... Show Details
[J-GATE3.0] Is [match_group_nbr_u] (Match Group Number) unique for each business day? When does i...
Although [match_group_nbr_u] (Match Group Number) is numbered per business day, there are cases that separate BD6 may hold the same value; therefore, would n... Show Details