[J-GATE3.0]Is there any time range in which SCB (Static Circuit Breaker) is not applied with rega...
SCB shall not be applied after 20 minutes prior to closing, even if it meets the condition to apply SCB. For the detail, please refer to the "Conditions f... Show Details
[J-GATE3.0] How can users acquire BO5 data without API?
API is the only way to retrieve BO5 data. In terms of providing order information, JPX provides "Alternative Data Service" which is fee-charging. This orde... Show Details
[J-GATE3.0] Regarding BD2 (Four Prices (High, Low, Open, Last/Close) Information / Index Informat...
Output time and dissemination time on BD2 (Four Prices (High, Low, Open, Last/Close) Information / Index Information) is provided in seconds and no less than... Show Details
[J-GATE3.0] Order was resulted in error, and we got error code “-475093”. Please tell us the rea...
The error code “-475093” occurs when the 1st byte of [exchange_info_s] (Client or House field) is incorrect. Show Details
[J-GATE3.0] What is a member number? Is the member number fixed value?
Member number is a value that is set to [cst_id_n] of DA6, which is an answer to DQ6 (Broker Information). If the sponsoring sub-participant wishes to recei... Show Details
[J-GATE3.0]Is STP function able to switch to enabled/disabled?
STP function cannot switch to enabled/disabled per order. To enable/disable STP, the user needs to apply per sub-participant via arrowface. Moreover, sin... Show Details
[J-GATE3.0] With regard to combination series, does combination of options and futures exist?
Combination series composed of futures and options does not exist. Combination series are only composed with futures series. Show Details
[J-GATE3.0] Will different values be set to [match_group_nbr_u] (Match Group Number) for each exe...
"0" is set to [match_group_nbr_u] (Match Group Number) in all BD6 when normal order is executed with multiple orders in a single deal. On the other hand, di... Show Details
[J-GATE3.0] How can we make sure that we don't miss any multicasts during Weekend Testing?
Just same as the normal Production Environment; all the multicasts are available as long as subscribing to multicast from 1 hour prior to online until on... Show Details
[J-GATE3.0] Is there a case that structure 37805 is not set for the answer (DA90) of DQ90(request...
Structure 37805 is always set even when DA90 is divided into segments. There are no case that structure 37805 is not to be set. Show Details