[J-GATE3.0] If the expiration date of a securities options is adjusted, is it possible to identif...
For series which has been added due to adjustment of the expiration date, [modifier] (change number) in DQ124 (DA124) will not be [0] but will be set with va... Show Details
[J-GATE3.0] Login to J-GATE is rejected, please investigate if there is any issue.
JPX will investigate the issue. Please send the below information to JPX Service Desk (J-GATE) at j-gate3@jpx.co.jp by email. - Date/Time of Occurrence (... Show Details
[J-GATE3.0] What is the expected behavior when a value is inserted to reserved 32nd byte (for TOC...
If a value other than recommended value (space), which is described in “J-GATE3.0_Connectivity_Manual_Business_Message_part”, is inserted to reserved 32nd by... Show Details
[J-GATE3.0] Is [match_group_nbr_u] (Match Group Number) unique for each business day? When does i...
Although [match_group_nbr_u] (Match Group Number) is numbered per business day, there are cases that separate BD6 may hold the same value; therefore, would n... Show Details
[J-GATE3.0] Regarding BD2 (Four Prices (High, Low, Open, Last/Close) Information / Index Informat...
Output time and dissemination time on BD2 (Four Prices (High, Low, Open, Last/Close) Information / Index Information) is provided in seconds and no less than... Show Details
[J-GATE3.0]Although the login ID was disconnected for less than 1 second, Auto-Cancellation Funct...
Auto-Cancellation Function will be triggered when a login ID has been forcefully logged out. Moreover, login IDs will be forcefully logged out if there is n... Show Details
[J-GATE3.0] How can users acquire BO5 data without API?
API is the only way to retrieve BO5 data. In terms of providing order information, JPX provides "Alternative Data Service" which is fee-charging. This orde... Show Details
[J-GATE3.0] What is the maximum value of information to be obtained by one polling/ query?
Up to 64,000 bytes of information can be obtained with one polling or query. If more than that numbers are defined, the error code "-2004" will be output. Show Details
[J-GATE3.0] Is it possible to change the number of attempts until Login ID is locked?
Login ID will be locked after 5 attempts of login with an incorrect password. It is not possible to change the number of attempts until the Login ID is lock... Show Details
【J-GATE3.0】What is the preliminary and fixed value of index information in BD2?
The preliminary value and fixed value for index are provided after the end of a whole trading day, morning and afternoon session. The preliminary value and ... Show Details
1-10 of Total 164