JPX Service Desk
FAQ Site (Application FAQ / System Support FAQ)
  • Font Size
  • S
  • M
  • L

Contacts for JPX Service Desk

Application Procedure contact
Open Hours: Business day 9:00 am - 6:30 pm
TEL: +81-50-3819-1070
Email: servicedesk@jpx.co.jp
arrownet support contact
Open Hours:
  Japanese) 24/7
  English) 7:00 am - 6:30 pm on business days
TEL: +81-50-3819-1030
Email: arrownet_support@jpx.co.jp
arrowhead/ToSTNeT contact
Open Hours: Business day 7:00 am - 6:30 pm
TEL: +81-50-3822-8882
Email: arrowhead@jpx.co.jp
J-GATE contact
Open Hours:
  Japanese) 24/7
  English) 7:00 am - 6:30 pm on business days
TEL: +81-50-3822-8900
Email: j-gate3@jpx.co.jp
Clearing contact
Open Hours: Business day 9:00 am - 5:00 pm
TEL: +81-50-3819-1076
Email: servicedesk_clearing@jpx.co.jp
  • No : 10657
  • Updated Date : 2021/03/17 14:08
  • Modified on : 2023/01/19 09:50
  • Print

[J-GATE3.0] Can we place orders with closing condition of "M_PRE_CLOSE" for next day in advance?

Can we place orders with closing condition of "M_PRE_CLOSE" for next day in advance?
Category : 

Answer

As an example, please set as below if you would like to place closing condition order of "M_PRE_CLOSE" effective on the next business day (will be referred to as t+1).
 
time_validity_n = 1282 (GTD 2 days)
exch_order_type_n = 512 (Trigger on session)
ext_t_state_c = 1 (M_PRE_CLOSE)
order_type_c = 1 (Limit)
 
Please note that FAK orders with the closing condition “M_PRE_CLOSE” placed on day t will not be taken over to t+1 since the order type is neither GTD nor GTC, and will expire at “J-NET_END” of day t.
Therefore, FAK order which will be effective at "M_PRE_CLOSE" on t+1 cannot be placed on day t.
 
time_validity_n = 0 (FAK)
exch_order_type_n = 512 (Trigger on session)
ext_t_state_c = 1 (M_PRE_CLOSE)
order_type_c = 1 (Limit)
 
Furthermore, closing condition orders for particular products which do not have the relevant TSS (as if some products in TOCOM do not have M_PRE_CLOSE as TSS) are not valid.
To confirm timetable of each product and availability of the desired TSS, please refer to “5.1 (1) Time Table Involving Each Product Categorization” and “5.1(2) Timetable by Category” on [J-GATE3.0_Connectivity_Manual_Business_Message_part_Appendix].